Control and indicating devices of burglar and fire alarm: "А6-02", "А6-04", "А6-06"
![]() |
System Peculiarities:
CONTROL AND INDICATING DEVICES OF BURGLAR AND FIRE ALARM: "A6–02", "A6–04", "A6–06""A6–02", "A6–04", "A6–06" devices are applied in fire and burglar alarm systems and for access control at small – sized units: appartments, cottages, shops, warehouses, offices. They control the status of 2, 4 and 6 loops accordingly and operate with different types of burglar, fire and alarm detectors.The devices transmit the events data of the unit to Centralized Station using different information channels. The data can be transmitted simultaneously via two or more communication channels. The following system protocols are built into "A6" panels: "STARS", "Mayak", "Alesia", "Cortex", "Ademco". As a communication channel there can be used a radio channel, phone network busy lines, interfaces RS232, RS485, Ethernet. The devices can be programmed by one of the following methods: from a console, from VPU–A–06 Keypad or PC. The "A6" devices have the built–in uninterruptible power supply units and a room in the case for placing the storage battery of up to 7Ah. In the devices of "A6–06KD" modification, access control functions are broaden up to 5 000 e–keys and 5 000 events. Technical characteristics:
Indication:
![]() Monitoring system operation:
VPU–A–06 KEYPADVPU–A–06 Keypad (with an LCD) displays in the text mode the data of system events, loops and equipment statuses, allows the command of Fire and Burglar Alarm Zones. Up to 8 controllable "A6" devices can be connected to one keypad via communication line RS485. "A6" devices are programmed by means of VPU–A–06 Keypad. ![]() RM–64–2, RM–64–6 RELAYS MODULESRM–64–2 and RM–64–6 modules serve for increasing the number of relays correspondingly for 2 and 6 pieces. Each relay has its own logics and kind of operation that is programmed using individual scripts. The modules can control the devices of different functional area or transmit signals to CCS. AUTOMATIC CALLING MODULE IS–RF/ADIS–RF/AD automatic Calling Module is meant for transmitting information from series "A" devices via telephone lines using standard protocols: Ademco Contact ID and 4+2. When a device records a new event, IS–RF/AD Module comes into the state of calling to one of the programmed earlier telephone numbers and, having received the signal "ready", transmits the data of the event occurred. ![]() ![]()
COORDINATION MODULES: IS–RF, IS–RF/ACoordination Module IS–RF provides series "A" devices operation as component parts of "MAYAK", "STARS", "IRBIS", "Andromeda", "PIMA" systems, where data transmission to Central Control Station is carried out via a radio channel. Coordination Module IS–RF/A serves for connecting series "A" devices to RS–202TC transmitter and their common operation as component parts of "Rif String–202" (Altonica) radiosystem of message transmitting. IS–RF/A Module provides series "A" devices operation with other systems working via Ademco Contact ID protocol. ![]() ![]()
REPEATER R485–АThe repeater Р485–А serves for creating random topology and protecting interface RS485 communication line from "Short Circuit" and "Cut". It can also be used for lengthening the communication distance for 1 200 m. It determines automatically the direction of data transmission between two segments and disconnects the defective segment from the rest of the network. ![]() IТЕRFACES MODULES: IS–ETH, IS–485, IS–232, IS–USBIS–ETH Module provides functioning of series "A" devices in the local networks via the protocol TCP/IP. IS–485 Interface Module serves for connecting series "A" devices to the local bus of data exchange of RS485 standard in order to unite the devices into an integrated system of fire and burglar alarm and access control "Network A". IS–232 and IS–USB Modules connect the series "A" devices to PC via interfaces RS232 and USB accordingly for programming or remote control of their status. ![]() ![]() RECEIVING AND INDICATING DEVICE OF FIRE AND BURGLAR ALARM: "А16–512"Receiving and Indicating Device of Fire and Burglar Alarm PPKOP "A16–512" with access control function serves for creating security systems for middle–sized units – schools, kindergartens, shops, warehouses, banks, offices, residential and administrative houses. PPKOP "A16–512" programming principle allows to model scripts and modes of operation of different executive devices, create individual settings for every task and unit, group freely loops into zones, and program the operation thresholds for every fire alarm loop. The device is provided with "repeated alarm" function. Built–in lightning protector, high informativity and reliability, different modes of messages communication, including simultaneous transmission via a radio channel and phone lines, give advantages to "A16–512" devices in comparison with the analogues when using them in monitoring systems. The following system protocols are built in "A16–512" devices: "STARS", "Mayak", "Alesia", "Cortex", "Ademco". As a communication channel there can be used: a radio channel, busy phone lines, interfaces RS232 and RS485 interfaces, Ethernet. Component parts of "A16–512":
The base block of PPKOP "A16–512" provides the control of 16 fire and burglar alarm loops and consists of a processor module and impulse power supply unit of 3A/12V. The extension of device up to 48 loops is carried out by the addition of 2 modules AP–16 to the base block. The further capacity extension is possible by way of PPKOP "A16–512" base blocks connecting via KSO–A System Controller to VPU–A–16 keypad where the status of all 512 loops (zones) is displayed. Technical characteristics:
![]() ![]() Control of:
ADD–ON MODULE FOR 16 LOOPS "AR–16"The AP–16 is an add–on module for 16 burglar and fire alarm loops. It is connected to A16–512 via RS 485 communication line and has 2 relays (3A/30V) with possibility of expansion to up to 8 relays thanks to modules PM–64–6. ![]() ![]() KEYPADS: VPU–A–16 AND AMI–16VPU–A–16 is a keypad with an LCD. It displays in the text mode the data on system events, loop and equipment status, allows the control of burglar and fire alarm zones. AMI–16 module is a LED keypad. It controls 48 burglar and fire alarm zones and displays their status. It is possible to connect to one device A16–512 (irrespective of zones number) up to 3 any keypads for arranging observation stations. ![]() MODULE OF CONNECTING 8 ACCESS DEVICES "AMS–8"Up to 8 devices in any combination can be connected to the module AMC–8: code panel, Proximity card reader, Touch Memory card reader. The module is connected to "A16–512" via RS 485 communication line. It allows creating 8 additional independent card– reader channels for control of corresponding zones with individual status indication for each zone. ![]() ![]() FIRE ALARM DEVICE: PPKOP "A16–512P"PPKOP "A16–512P" serves for arranging fire alarm systems at low–budget units.
![]() INTEGRATED SYSTEM OF BURGLAR AND FIRE ALARM AND ACCESS CONTROL "NETWORK A""Network A" is destinated for building security complexes of small– and medium–sized units. It integrates the functions of security, perimeter, buglar and fire alarm subsystems, and subsystems controlling the automated devices of notification, smoke removal, fire fighting, access control and video surveillance. The system is built up by receiving and indicating devices "A6–02", "A6–04", "A6–06", "A16–512" and control fire device "Obereg", as well as the loop module of polling addressable detectors MASh XPA6. They are connected to the processor module KSO–А via communication line RS485 and further to the Automated Working Place of Duty Operator (Central Control Station PC). It is possible to start the creation of security complex with the installation of one autonomous device and gradually increase the quantity to 1536 loops per one PC COM port. "Network A" is a classic example of dispersed intelligence system, in which the configurations and data bases can be kept at three levels: Central Control Station PC, controllers KSO–A and in each series "A" device. "Network A" has an open architecture and can transmit full data as from unit level (series "A" devices), so from controller level (KSO–A) via three independent ports by data communication protocol to the external CCS. It is also possible to regulate the mode of data communication: on the whole device, on each device zone, on each device loop and in any combinations. The connection to KSO–A of module RM–64–6 allows the control of 6 general–system relays, and their operation mode is set individually connected to any event controlled by the system. "Network A" is provided with serial ports for connecting to and operating in monitoring systems: "Alesia", "Ademco", "STARS", "Irbis", "Mayak", "Nioman" by phone and power network, Ethernet, GSM and radio channel. Technical characteristics:
The software: The software "Configurator" allows the remote programming of every device, the creation of unit individual configuration, registration and cancelling of user keys, placing video cameras, detectors and annuciators icons in the graphic plans of a unit connected to its Alarm Zones. The software "AWP DO" serves for creating automated working place of duty operator and provides:
Functions:
![]() ![]() SECURITY SECTOR CONTROLLER "KSO–A"KSO–A allows to unite "A6" and "A16–512" devices in one system. It controls the zones and programs all devices connected to it. Data displaying about system events and commands entering are carried out from the keypad VPU–A–16. When connected to the transmitter, KSO–A controller sends via a radio channel to the CCS the messages on 64 zones status and events in the system.
![]() STRUCTURE CHAT "NETWORK А"![]() | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||